1.Overview

The electric refueling pump is suitable for the dry oil centralized lubrication system. The oil reservoir of the electric lubrication pump is filled with lubricant. The pump is a built-in plunger positive displacement pump. Suction oil function. The pump runs smoothly and has a high output pressure. It is equipped with a low oil level alarm device, which can fill the oil cylinder with grease in time.


2.Technical parameters

智能润滑制造

Use medium with a penetration of not less than 265 (25 ° C, 150g) 1 / 10mm grease (NLGI 0 # ~ 2 #) or industrial lubricant with viscosity grade greater than N46


3.Instructions for use

       

1. Before use, unscrew the oil plug above the casing and add No. 50 mechanical oil to the specified oil level.


2. Rotate the wire in the direction of the arrow.


3. The smart lubricant delivered must be clean, uniform in texture and within the specified viscosity range.


4. The nominal pressure of the pump is 3MPa, which has been adjusted at the factory, and no further adjustment is necessary.


5. When leaving the factory, the inner diameter of the hose is Φ13, and the external connection thread is M33 × 2. If the connection thread of the lubrication pump filler port is M32 × 3, use a spare transition joint.


6. The pump is equipped with a low-level alarm device. After the alarm, the oil barrel should be filled with grease in time.


7. Do not run dry without oil in the barrel.


4.Dimensions

干稀油润滑


5.Failure and troubleshooting

       

1. No oil discharge:


a. There is air in the lubricant, loosen the exhaust valve to exhaust the air in the lubricant, and tighten the exhaust valve.


b. The oil suction port is stuck to the impurities. Do not suck or pressurize the oil.


2. Low oil pressure:


a. Check whether the check valve in the pump is jammed or damaged, and clean or replace the check valve.


b. Check whether there are leaks in the seals and pipe joints, replace the seals and tighten the joints.



6.spare parts

        Transition joint (external thread M33 × 2 / internal thread M32 × 3)

label

Previous:DJB-V70Electric gasoline pump2020-01-13

Recently Viewed:

Product center
Dry oil lubrication part
Thin oil lubrication
Smart lubrication
Process lubrication
About us
Company Profile
Honor
Contact us

Address: No.010 Xinglong Road, Huilong Industrial Park, Qidong City

Hotline:0513-83637668 

Company Fax:0513-83637098 

After sales service:0513-83635700

URL:www.qdhsrh.com

Website :en.qdhsrh.com

E-mail:qd3637668@163.com

工艺润滑公司

Scan to learn more