1.Conditions of Use
SSV series single line progressive distributor is suitable for single machine or small dry thin oil single line centralized lubrication system with nominal pressure below 30M Pa. It relies on a piston inside the housing to reliably and forcibly distribute the lubricant input from the inlet in a predetermined amount. This type of distributor has oil outlets on the left and right sides. The installation dimensions are the same for different numbers of outlets. The outlets are derived and combined to increase the oil supply. The connection with a manual, pneumatic or electric dry thin oil lubrication pump can be simple and inexpensive Small centralized lubrication system can also be connected to single-line or double-line distributors in large centralized lubrication systems as auxiliary distributors for secondary distribution.
2.Technical Parameters
Use a grease with a cone penetration greater than 265 (25 ° C, 150g) 1 / 10mm, (NLGI 0 # ~ 2 #). If lubricating oil is used, the viscosity grade is greater than N68.
3.Model Description
4.Dimensions
1. Oil outlet: φ6 (the grease nipple component is already installed at the factory)
2. At 25 ℃, the maximum pressure loss of the lubricant through the distributor is 1-2MPa.
5.Action description
The lubricant enters the distributor in the direction of the arrow and is pressed to the right of piston A
Lateral end. The piston A moves to the left by the lubricant pressure. lie in
The lubricant on the left front end of piston A is transported to the drain through the internal channel of the housing.
Outlet 2 then passes through the lubrication position pipe to the friction position.
When piston A reaches its left end position, it goes to piston B right
The connection channel at the side terminal position is open. Lubricant flows to piston B right
The end of the side moves the piston B to the left. Located in front of the left side of piston B
The lubricant at the end is conveyed to the discharge port 7 through a channel inside the housing.
When piston B is in its left end position, it makes the way to live
The connection channel at the right end of plug C is opened, so that the lubricant is under pressure
Force flows and moves piston C to the left. And located on piston C
The lubricant on the left front end is delivered to the discharge port 5.
The connection channel to piston D is now open and the lubricant pressure
To the right end of piston D. Lubricant on the left front end of piston D
It will be output from exhaust port 3.
When piston D opens the connection channel to the left terminal of piston A
After that, the lubricant flows and pushes piston A to the right. Located in front of piston A
The lubricant on the right is delivered to the discharge port 1.
At this time, the pistons B to D move from the left to the right.
Direction sequence action completes a cyclic cycle and can restart one
New cycle.
6.Instructions for use
1. It is recommended to use at most "two levels" in the system for lubricant distribution.
2. Drain ports 1 and 2 cannot be closed at all times.
3. Always use the original exhaust port and nozzle assembly.
4. When assembling, disassembling and changing the nozzle parts, start from the upper or lower part of each side.
5. If the discharge port is to be closed and recombined, and the lubricant quantity is changed (flow to the lower discharge port below), the grease nipple body must be removed and plugged with M10 × 1 screw plug as shown in the example below.
7.Troubleshooting and troubleshooting
A blockage has occurred in the equipment or in any of the connected bearings. First check whether the lubricating pump is working and whether the lubricant is given to the main distributor. The lubricant will overflow when the distributor's oil inlet connector is opened, proving that the distributor is the source of the fault. Connect the oil inlet connector and tighten it, then open the oil inlet connector of the bearing in turn, and the lubricant overflows, then this bearing is a blocked bearing.
When the dispenser becomes internally blocked, the dispenser should be replaced. In an emergency, the dispenser can be cleaned according to the following conditions.
1. Must have a clean working area.
2. Remove the inlet and outlet connectors.
3. Remove the screw plugs at the two ends of the piston hole.
4. Push out the piston with a soft mandrel (diameter less than 6mm, plastic rod if possible).
5. Blow and clean the dispenser body with compressed air.
6. Using a thin iron wire (Φ1.5mm), check the oblique hole of the flow channel in the distributor.
7. Clean and spray the dispenser body again.
8. Replace the copper gasket and reassemble the distributor.
9. Use a manual pump to check the newly assembled distributor. At this time, the starting pressure of the distributor cannot be higher than 2.5M Pa. If the starting pressure is higher than 2.5M Pa, the distributor should be replaced.